Migrating VMware vSphere In-tree to Out-of-tree
Kubernetes is moving away from maintaining cloud providers in-tree. VMware vSphere has an out-of-tree cloud provider that can be used by installing the vSphere cloud provider and cloud storage plugins.
This page covers how to migrate from the in-tree vSphere cloud provider to out-of-tree, and manage the existing VMs post migration.
It follows the steps provided in the official vSphere migration documentation and provides the steps to be performed in Rancher.
Cloud-config Format Limitation
Existing volumes that were provisioned using the following cloud-config format won’t get migrated due to an existing bug in vSphere Cloud Storage Interface (CSI).
If the cloud-config has this format for datastore and resource pool path, vsphere CSI driver cannot recognize it:
default-datastore: </datacenter>/datastore/<default-datastore-name>
resourcepool-path: "</datacenter>/host/<cluster-name>/Resources/<resource-pool-name>"
Volumes provisioned with the in-tree provider using the following format will get migrated correctly:
default-datastore: <default-datastore-name>
resourcepool-path: "<cluster-name>/Resources/<resource-pool-name>"
Rancher issue tracking this bug: https://github.com/rancher/rancher/issues/31105
Prerequisites
-
vSphere CSI Migration requires vSphere 7.0u1. In order to be able to manage existing in-tree vSphere volumes, upgrade vSphere to 7.0u1.
-
The Kubernetes version must be 1.19 or higher.
Migration
1. Install the CPI plugin
Before installing CPI, we need to taint all nodes with node.cloudprovider.kubernetes.io/uninitialized=true:NoSchedule
.
This can be done by running the following commands:
curl -O https://raw.githubusercontent.com/rancher/helm3-charts/56b622f519728378abeddfe95074f1b87ab73b1e/charts/vsphere-cpi/taints.sh
Or:
wget https://raw.githubusercontent.com/rancher/helm3-charts/56b622f519728378abeddfe95074f1b87ab73b1e/charts/vsphere-cpi/taints.sh chmod +x taints.sh ./taints.sh <path to kubeconfig if running the command outside the cluster>
Once all nodes are tainted by the running the script, launch the Helm vSphere CPI chart.
-
Click ☰ > Cluster Management.
-
Go to the cluster where the vSphere CPI chart will be installed and click Explore.
-
Click
. -
Click vSphere CPI.
-
Click Install.
-
Fill out the required vCenter details and click Install.
vSphere CPI initializes all nodes with ProviderID, which is needed by the vSphere CSI driver.
Check if all nodes are initialized with the ProviderID with the following command:
kubectl describe nodes | grep "ProviderID"
2. Install the CSI driver
-
Click ☰ > Cluster Management.
-
Go to the cluster where the vSphere CSI chart will be installed and click Explore.
-
Click
. -
Click vSphere CSI.
-
Click Install.
-
Fill out the required vCenter details and click Install.
-
Check Customize Helm options before install and click Next.
-
On the Features tab, check Enable CSI Migration.
-
Optionally, go to the Storage tab and set up a datastore. This chart creates a StorageClass with the
csi.vsphere.vmware.com
as the provisioner. You can provide the URL of the datastore to be used for CSI volume provisioning while creating this StorageClass. The datastore URL can be found in the vSphere client by selecting the datastore and going to the Summary tab. Fill out the details for the StorageClass. -
Click Install.
3. Edit the cluster to enable CSI migration feature flags
-
While editing the cluster, if the Kubernetes version is less than 1.19, select Kubernetes version 1.19 or higher from the Kubernetes Version dropdown.
-
For enabling feature flags, click on "Edit as YAML", and add the following under kube-controller and kubelet:
extra_args: feature-gates: "CSIMigration=true,CSIMigrationvSphere=true"
4. Drain worker nodes
Worker nodes must be drained during the upgrade before changing the kubelet and kube-controller-manager args.
-
Click ☰ > Cluster Management.
-
Go to the cluster where you will drain worker nodes and click ⋮ > Edit Config.
-
In the Advanced Options section, set the field Maximum Worker Nodes Unavailable to 1.
-
To drain the nodes during upgrade, select
. -
Set Force and Delete Local Data to true.
-
Click Save to upgrade the cluster.